PDA series

PDA23V

Duplex fully automatic water softener for removing hardness (calcium, magnesium). Two filter vessels and two brine tanks ensure a continuous supply of soft water, including during backwashing. Nominal flow rate: 2 m³/h · Capacity: 56 m³ · Dimensions: 1620 x 510 x 1530 mm
Nominal flow rate2 m³/hCapacity56 m³Dimensions1620 x 510 x 1530 mm
Request a quote for this product

We usually reply within 1 hour on business days.

Category:

Description

Problem

Water hardness.

Unit description

The water softener is designed to remove hardness (i.e. the calcium and magnesium ions contained in the water). The water treatment unit consists of two vessels filled with filter media, a fully automatic controller that manages the filter’s operation and two brine tanks. The filter medium is an ion exchange resin made specifically for water treatment.

Intended use

The unit is used when treated water must be available at all times (including during backwashing). The unit can be started in two ways: duplex unit (the filter vessels work alternately) or parallel unit (the filter vessels work at the same time but go into backwashing at different times).

Operating principle

In the unit, the calcium and magnesium ions dissolved in the water are replaced with sodium ions. The unit works fully automatically, performing backwashing, i.e. regeneration, according to consumption. The user’s task is to make sure there is always enough of a supply of salt tablets in the brine tank. The installation site needs an electrical outlet and a drain connection.

Technical data

Flow rate, nominal 2 m³/h**
Flow rate, maximum 2.5 m³/h**
Operating pressure 2–8 bar
Operating temperature +5 to +30 °C
Electrical connections 230 VAC / 50 Hz
Capacity at total hardness of 1 meq/l 56 m³**
Regeneration* salt consumption 5.5 kg**
Regeneration* water consumption 330 l**
Filter media ion exchange resin, support gravel
Unit dimensions (L x W x H) 1620 x 510 x 1530 mm
Connections (inlet, outlet, drain) 1” male thread, 1” male thread, 12 mm
Brine tank 90 l**

* Salt and water consumption are calculated per regeneration at an inlet pressure of 3.4 bar (under the standard program). ** Data given for one filter vessel.

Unit components

  1. Controller
  2. Timer
  3. Filter vessel
  4. Upper screen
  5. Filter media
  6. Center tube
  7. Support gravel
  8. Lower screen
  9. Air valve
  10. Brine hose
  11. Brine tank
  12. Brine well
  13. Salt tablets
  14. Brine solution

Unit connections

  • Outlet – 1” male thread
  • Drain – 12 mm
  • Inlet – 1” male thread
Miridon company building in Tartu

Write to us

Tartu office

Tallinn office