  • Removes calcium and magnesium ions from the water
  • Protects boilers, heat exchangers, circulation pumps, distribution manifolds, plumbing, household appliances and pipework from limescale deposits
  • Improved energy efficiency
  • Ensures stable water quality and reliability even under high consumption loads
  • The solution is selected based on the water analysis, consumption and the requirements of the production process

Every business needs clean water of stable quality

Hard water causes limescale to form in pipework and equipment, increases energy costs and shortens equipment life. In industrial processes and large buildings, where water consumption is considerable, water softening is essential to ensure reliable production and lower maintenance costs.

Miridon supplies water softening equipment for boiler houses, laundries, hotels, restaurants, food processing plants and other industrial sectors.

Professional systems ensure an uninterrupted supply of softened water, even under heavy consumption loads. The units operate fully automatically according to the configured consumption.

Softened water contributes to greater energy efficiency, reduces maintenance costs and extends the life of pipework and production equipment.

 

Standard solutions – lower capacity (5-20 m³/h)

  • The units have their own controller, which manages the automatic operating and regeneration cycle.
  • The units can be used individually or in combination.
  • A common solution is a two-unit system where one unit is in operation and the other on standby – this ensures continuous availability of softened water.
  • When used in parallel, the controllers are linked to prevent the units from regenerating at the same time.

 

Project-based solutions – high capacity

When water consumption is high, we configure the equipment on a project basis according to the customer’s input data and the water analysis results. This ensures maximum reliability of the system and its suitability for the specific production process.

Note: to ensure efficient operation of water treatment equipment and optimal water quality, we recommend following the manufacturer’s instructions for installation, use and maintenance.

Read more

A personal solution to your water problem

1

Water analysis

Open/close more info

Water analysis is the foundation of a reliable water treatment solution.

The journey to clean water starts with taking a water sample. Miridon's accredited water laboratory analyzes the composition of the water based on chemical and microbiological parameters to identify the sources of problems – whether excess iron, the causes of hardness or microorganisms.

We also offer a certified water sampler service.

Call +372 526 8515 or send an inquiry labor@miridon.ee

2

Consultation

Open/close more info

We approach every customer's needs personally.

Based on the analysis results, we give a personal recommendation on which solution suits your water problem best. Our specialists can help interpret the analysis results when needed and find the best option, one that takes into account both the specific nature of your water and your needs. 

Call +372 506 6775 or send an inquiry miridon@miridon.ee

3

Installation

Open/close more info

We help with the correct installation of equipment.

Professional installation ensures trouble-free operation of the equipment and an optimal purification result. Miridon's technicians are experienced and thoroughly trained – so you can be confident that the chosen equipment is installed in line with all requirements and best practices.

Call +372 506 6775 or send an inquiry miridon@miridon.ee

4

Maintenance service

Open/close more info

Service your equipment at least once a year.

Even the best water treatment equipment needs regular maintenance. We recommend servicing at least once a year to ensure the equipment's reliability, efficiency and long service life. Miridon's maintenance service includes a technical inspection of the equipment, cleaning (including cleaning of the salt tank when necessary) and an express water analysis.

We also replace filter media.

Benefits of a maintenance contract:

Regular maintenance is important for keeping the water quality up.

Call +372 506 6775 or send an inquiry miridon@miridon.ee

  • As a reliable partner, Miridon offers fast, high-quality maintenance service across Estonia
  • Our customer service serves contract customers with priority, and the maintenance team responds to a call within up to 72 hours
  • The contract guarantees better prices for maintenance service, spare parts and water treatment chemicals (salt)
  • Express water analysis is always free of charge for contract customers
5

Give feedback

Open/close more info

Dear customer, please share your suggestions with us.

At Miridon, it is important to us that, together with our customers, we can improve and develop our service and the quality of our services. We are grateful if you give us advice by answering the questions that open from the link.

Possible solutions

Based on the water analysis results, our sales team will help you choose the right equipment.

 

PDA series

The unit is designed to remove hardness (i.e. the calcium and magnesium ions contained in the water).

The unit is used when treated water must be available at all times (including during regeneration).

The unit can be operated in two ways.

  1. Duplex unit – the filter vessels work alternately, i.e. one vessel is in service while the other is on standby. When the capacity of the first vessel is exhausted, the second vessel goes into service and the first goes into regeneration. When regeneration finishes, the vessel remains on standby until the capacity of the other vessel is exhausted. The duplex unit is the most efficient, because the useful capacity can always be used up completely without the risk of hard water leaking into the outlet.
  2. Parallel unit – the filter vessels work at the same time but go into regeneration at different times. Each vessel has its own water meter, which the unit uses to decide when regeneration is needed. While one vessel is regenerating, the other keeps working and supplies the consumer with softened water. When regeneration ends, the first vessel resumes work and the second goes into regeneration when necessary. For this reason, the regeneration start of a parallel unit is programmed with a small margin. A parallel unit is used when a continuous supply of softened water is important, but the capacity of a single vessel is occasionally insufficient and, for technical reasons, larger vessels cannot be used.

The unit removes calcium and magnesium ions from the water, replacing them with sodium ions. The unit works fully automatically, performing regeneration (backwashing) according to consumption. The user’s task is to make sure there are always enough salt tablets in the brine tank. The installation site needs an electrical outlet and a drain connection.

Note: the drain must be able to take the backwash flow rate. We recommend consulting our sales team beforehand.

 

MGD series

The unit is used when treated water must be available at all times (including during backwashing).

The unit can be started in two ways.

  1. Duplex unit – the filter vessels work alternately, i.e. one vessel is in service while the other is on standby. When the capacity of the first vessel is exhausted, the second vessel goes into service and the first goes into regeneration. When regeneration finishes, the vessel remains on standby until the capacity of the other vessel is exhausted. The duplex unit is the most efficient, because the useful capacity can always be used up completely without the risk of hard water leaking into the outlet.
  2. Parallel unit – the filter vessels work at the same time but go into regeneration at different times. Each vessel has its own water meter, which the unit uses to decide when regeneration is needed. While one vessel is regenerating, the other keeps working and supplies the consumer with softened water. When regeneration ends, the first vessel resumes work and the second goes into regeneration when necessary. For this reason, the regeneration start of a parallel unit is programmed with a small margin. A parallel unit is used when a continuous supply of softened water is important, but the capacity of a single vessel is occasionally insufficient and, for technical reasons, larger vessels cannot be used.

The unit removes calcium and magnesium ions from the water, replacing them with sodium ions. The unit works fully automatically, performing regeneration (backwashing) according to consumption. The user’s task is to make sure there are always enough salt tablets in the brine tank. The installation site needs an electrical outlet and a drain connection.

Note: the drain must be able to take the backwash flow rate. We recommend consulting our sales team beforehand.

 

MGV series

The unit is designed to remove hardness (i.e. the calcium and magnesium ions contained in the water). The water treatment unit consists of a vessel filled with filter media, a fully automatic controller that manages the filter’s operation, and a brine tank. The filter medium is an ion exchange resin made specifically for water treatment.

The unit removes calcium and magnesium ions from the water, replacing them with sodium ions. The unit works fully automatically, performing regeneration (backwashing) according to consumption. The user’s task is to make sure there are always enough salt tablets in the brine tank. The installation site needs an electrical outlet and a drain connection.

Note: the drain must be able to take the backwash flow rate. We recommend consulting our sales team beforehand.

 

MGVT series

The unit is used when treated water must be available at all times (including during regeneration).

Parallel unit – the filter vessels work at the same time but go into regeneration at different times. Each filter vessel has its own water meter, which the unit uses to decide when regeneration is needed. When one unit is regenerating, the others do not start backwashing at the same time but wait until the regenerating unit has finished. For this reason, the regeneration start of a parallel unit is programmed with a small margin. A parallel unit is used when a continuous supply of softened water is important, but the capacity of one or two filter vessels is occasionally insufficient and, for technical reasons, larger vessels cannot be used.

The unit removes calcium and magnesium ions from the water, replacing them with sodium ions. The unit works fully automatically, performing regeneration (backwashing) according to consumption. The user’s task is to make sure there are always enough salt tablets in the brine tank. The installation site needs an electrical outlet and a drain connection.

Note: the drain must be able to take the backwash flow rate. We recommend consulting our sales team beforehand.

 

Installation and maintenance

  • We offer a full service – from taking water samples and installing the equipment to maintenance.
  • We also service equipment from other manufacturers.
  • We repair and configure the controllers of water treatment equipment from various manufacturers.
Read more
Not sure where to start?

Free advice. Free quote.

Miridon company building in Tartu

Write to us